Glens Key Lock & Safe Company
1147 South State Street, Salt Lake City, Utah 84111-4596 USA 

Phone 801.413.0577    Toll Free 800.451.9727    Fax 801-355-3414
Business Hours Mobile:
Monday - Friday
8:00 - 5:30
Business Hours Shop:    Monday - Friday 8:30 - 5:30
 Saturday 10:00 - 3:00

Home | Products | Down Loads | Site Map | Contact Us

"Save time, try us first"

OPERATING  INSTRUCTIONS for the Common Three Number Dial Safe Locks
READ THESE INSTRUCTIONS THOROUGHLY. Before operating the lock

At the top of the dial ring an index is provided for normal dialing and opening. At the side of the opening index, a changing index is provided for use only when setting a new combination.
This is a precision lock, therefore, extreme care must be used to align the combination numbers with the index.
Turn the dial slowly and steadily. If, after turning the correct number of revolutions, any number is turned beyond the index, the entire series of combination numbers must be re-dialed. DO NOT TURN BACK TO REGAIN A PROPER ALIGNMENT WITH THE NUMBERS. Each time a selected number is aligned with the opening index, a revolution is counted.

TO UNLOCK ON A FACTORY SETTING

TO UNLOCK ON FACTORY SETTING. TURN DIAL "LEFT" 4 TURNS, STOPPING ON "50", TURN DIAL RIGHT UNTIL BOLT RETRACTS.

TO UNLOCK ON A 3 NUMBER COMBINATION.

For Example "50-25-50"
1. Turn dial to the LEFT, stopping when "50" is aligned with the opening index, the FOURTH time.
2. Turn dial to the RIGHT. stopping when "25" is aligned with the opening index, the THIRD time.
3. Turn dial to the LEFT, stopping when "50" is aligned with the opening index, the SECOND time.
4. Turn dial slowly to the RIGHT until the bolt retracts.

TO LOCK

Turn dial to the LEFT at least four full revolutions.

CAUTION: BEFORE CLOSING THE UNIT, try the new combination several times, using the opening index.

Provided by SARGENT & GREENLEAF. INC., 1 Security Drive, Nicholasville, Kentucky 40356 630.112